Skip to content

Server environment ​

volumd reads its deployment configuration from environment variables.

VariableContainer defaultPurpose
VOLUM_CONFIG_DIR/configSQLite and server configuration directory
VOLUM_LIBRARY_DIR/libraryCanonical managed project library
VOLUM_BIND0.0.0.0:43821Listener address inside the container
VOLUM_PUBLIC_URLLoopback-derived outside ComposeReachable origin embedded in pairing payloads; required by the supplied Compose file
VOLUM_ORGANIZATION_WRITEStruePermit paired clients to edit organization and managed files
VOLUM_PHOTO_UPLOADStruePermit paired clients to add project photos independently of organization edits
VOLUM_PRINT_PAIRINGfalsePrint a fresh five-minute pairing payload at startup only when explicitly enabled
VOLUM_WEB_ENABLEDtrueServe the browser administrator and enable its authentication routes
VOLUM_WEB_DIR/usr/share/volum/webCompiled browser assets inside the container
VOLUM_ADMIN_PASSWORDUnsetBootstrap or reset the browser administrator password; minimum 12 characters

VOLUM_PUBLIC_URL ​

Use a complete http:// or https:// origin with no path, query, fragment, credentials, or trailing application route.

Valid examples:

dotenv
VOLUM_PUBLIC_URL=http://100.64.0.10:43821
VOLUM_PUBLIC_URL=http://volum-nas.example.ts.net:43821
VOLUM_PUBLIC_URL=https://volum.example.net

0.0.0.0 is a bind address, not a client destination.

Pairing output ​

Use the web administrator's Pair device action for normal onboarding. Set VOLUM_PRINT_PAIRING=true only for emergency log-based pairing. The printed payload contains a temporary secret and should be treated as sensitive until it expires or is consumed.

After pairing:

dotenv
VOLUM_PRINT_PAIRING=false

Web administrator ​

On the first start, set VOLUM_ADMIN_PASSWORD to at least 12 characters. Volum hashes it with Argon2id and stores only the hash under /config. Once that file is safely persisted, the clear-text environment value can be removed.

Supplying a different password later is treated as an operator-authorized reset. Existing administrator-browser tokens are revoked. Paired mobile and Desktop clients are not affected.

Write policy ​

Set VOLUM_ORGANIZATION_WRITES=false to block organization changes and 3D-file imports. Set VOLUM_PHOTO_UPLOADS=false to block project-photo uploads independently. The server enforces both policies even if a client interface displays an unavailable action.